Skip to content
TACHYONS ENERGYPRIVATE LIMITED

HV · EHV EPC  //  11kV – 440kV

Engineering the Backbone of Modern Power Infrastructure — From Generation to 440kV Transmission & Intelligent Substation Automation.

Turnkey excellence in High-Tension (HT) and Extra-High-Voltage (EHV) substation erection, control & relay panel engineering, heavy industrial cabling, and next-generation remote yard monitoring — delivered as one accountable EPC scope for utilities, EPC contractors and industrial plants.

Voltage classes engineered

  • 11kV
  • 33kV
  • 66kV
  • 110kV
  • 220kV
  • 440kV
Scope
Design · Supply · Erection · Testing · Commissioning
Practice
IEC / IEEE / CEA · KSEB / central grid
Base
Kerala, India

SLD · Generation → EHV → Distribution

ILLUSTRATIVE
Illustrative single-line diagram of a power systemAn 11kV generator feeds a generator transformer stepping up to a 440kV bus. A 440kV line bay with isolator, circuit breaker, current transformer and lightning arrester feeds a transmission line over lattice towers to a receiving substation, where an interconnecting transformer steps down to a 220kV bus, a power transformer to a 33kV bus, and a distribution transformer to an 11kV bus with outgoing feeders. Animated dashes show the direction of power flow.1234ABCDG1 · 11kVBreaker closed, protection healthy52GGT11/440kV440kV BUSSPARE BAY89LBreaker closed, protection healthy52LCTLA440kV TRANSMISSION LINETOWER EARTHINGBreaker closed, protection healthy52RICT440/220kV220kV BUSBreaker closed, protection healthy52TPTR220/33kV33kV BUSBreaker closed, protection healthy33-F1Breaker closed, protection healthy33-F2Breaker closed, protection healthy52DDT33/11kV11kV BUSBreaker closed, protection healthy11-F1Breaker closed, protection healthy11-F2Breaker closed, protection healthy11-F3Breaker closed, protection healthy11-F4LEGENDCIRCUIT BREAKER (52) · CLOSEDCIRCUIT BREAKER · OPENISOLATOR (89)CURRENT TRANSFORMERPOWER TRANSFORMERPOWER FLOW · ENERGISEDDRAWINGSLD · OVERVIEWSTATUSILLUSTRATIVESCALENTSREADOUTSSIMULATED
440kV bus
441.2kV
220kV bus
220.6kV
33kV bus
33.12kV
Frequency
50.00Hz

ALL BAYS CLOSED · PROTECTION HEALTHY

SIMULATED

Core power sector pillars

Generation, transmission and distribution — one engineering team across the chain

Every pillar is delivered as design, supply, erection, testing and commissioning, so interfaces between the plant, the EHV yard and the distribution network are owned by one team.

  • 01
    GEN → GRID · 11kV / 33kV / 110kV

    Plant-side electricals from the generator terminals to the point of grid interconnection.

    • Power plant balance-of-plant (BoP) electricals
    • Generator transformers
    • Synchronization panels
    • Commercial solar / renewable grid integration & evacuation
  • 02
    66kV · 110kV · 220kV · 440kV

    EHV switchyards and bays built, wired and proven ready for utility energisation.

    • EHV switchyard erection
    • SF6 circuit breakers and isolators
    • Current / potential transformers (CT/PT)
    • Busbar stringing and tower earthing
    • Numerical protection relays

    Field scope · typical

    • Structure erection, equipment alignment and busbar / jumper stringing to design sag and clearance
    • SF6 breaker erection, gas filling, dew-point, timing and contact-resistance tests
    • CT/PT polarity, ratio and knee-point checks; secondary injection of distance, differential and O/C–E/F relays
    • Switchyard earth mat and tower footing earthing with earth-resistance measurement
  • 03
    11kV · 33kV · LT

    HT and LT networks that carry power from the grid substation into the plant floor.

    • HT / LT switchgear
    • Ring Main Units (RMUs)
    • Distribution transformers
    • Underground armoured cable trenching & termination
    • Industrial plant electrification

Flagship innovation

Proprietary system

MoniTachThe Tachyons Yard Intelligence

220kV/440kV Smart Switchyard & Control Panel Remote Monitoring System

Real-time SCADA/IoT telemetry from the switchyard and the control & relay panel room, delivered to operators without anyone stepping inside the energised fence. High-voltage safety by design: the yard is observed, not visited.

  • Zero human exposure in the energised yard

    Breaker, CT/PT, gas-pressure and temperature states are read remotely, so no one enters a live 220kV/440kV yard just to read a gauge.

  • Optical-fibre galvanic isolation

    Field signals travel on fibre from yard to control room, keeping the data path electrically isolated from EHV potentials and induced surges.

  • Predictive diagnostics

    Trends on temperature, SF6 density and panel health flag drift before it becomes a trip, so maintenance is planned rather than forced.

  • Multi-substation command

    One SCADA/IoT view across several yards and control-panel rooms, with alarms, event history and live telemetry in one place.

Control-room view · preview

Simulated data

MoniTach

Simulated data · Demonstration console
Bay 204 · 220kV Feeder-1--:--:--

Breaker

CLOSED

Bus kV

220.1

Thermal

NORMAL

SF6 density @20°C

NORMAL

6.00bar

RATEDALARMLOCKOUT
Line current · 60 s420 A

Connecting to edge gateway…

How we deliver

One EPC chain, from survey to energisation

Each stage closes with a document the next stage depends on, so the yard that is energised is the yard that was designed, tested and inspected.

  1. STAGE 01

    Survey & design engineering

    Site survey and soil resistivity, then SLD, layout, earthing and protection-coordination drawings submitted for approval.

    SLD · Layout · BOQ

  2. STAGE 02

    Supply & erection

    Equipment procured to approved specifications; foundations, structures, equipment erection and busbar stringing.

    Erection records

  3. STAGE 03

    Control wiring & panel integration

    Control & relay panel wiring, cable schedules, terminations and interlock logic tied back to every yard bay.

    Scheme drawings

  4. STAGE 04

    Testing & commissioning

    Pre-commissioning tests on breakers, CTs, PTs and transformers; relay secondary injection and end-to-end scheme checks.

    Test reports

  5. STAGE 05

    Statutory inspection & energisation

    Electrical inspectorate and utility inspection, first energisation, as-built documentation and handover.

    Handover dossier

Trust & compliance

Adherence to safety and quality standards

Engineered and tested to IEC / IEEE / CEA and state-utility (KSEB / central grid) requirements — applied on the drawing board, in the yard and on the test bench.

  • Standard body

    IEC

    International Electrotechnical Commission

    Switchgear, protection, substation automation

    Switchgear, instrument-transformer and protection specifications referenced to IEC, with substation automation laid out on IEC 61850 communication principles.

  • Standard body

    IEEE

    Institute of Electrical and Electronics Engineers

    Grounding, protection and testing practice

    Earth-mat design with step and touch potential checks following IEEE 80 practice; test methods aligned to IEEE guides.

  • Standard body

    CEA

    Central Electricity Authority (India)

    Technical standards and safety regulations

    Electrical clearances, safety provisions and installation practice aligned to CEA technical standards and safety regulations.

  • State utility · central grid

    KSEB

    State utility and central grid requirements

    Utility specifications and inspection

    Utility technical specifications, protection-setting coordination and inspection requirements met for grid interconnection.

Statement of engineering practice — not a certification claim.

QUESTIONS & ANSWERS

What clients ask before a project starts

Short answers on what we do, the voltage levels we work at, solar and battery systems, and the MoniTach monitoring system.

Browse solutions by type of work

What does Tachyons Energy do?

Tachyons Energy Private Limited is a high-voltage electrical engineering and EPC company based in Kerala, India. It carries out HT and LT electrical works, erects substations and switchyards from 11kV to 440kV, builds and wires control and relay panels, lays and terminates HT/EHV cables, tests and commissions electrical equipment, and installs solar power plants with battery storage.

What is the difference between HT and LT electrical work?

LT (low tension) work covers installations up to 1kV, typically the 415V three-phase supply inside a building or plant. HT (high tension) work covers voltages above 1kV, such as 11kV and 33kV, and involves HT switchgear, transformers, protection relays and statutory inspection before energisation. Tachyons Energy handles both, and EHV work up to 440kV.

Which voltage levels does Tachyons Energy work at?

From LT distribution through 11kV and 33kV distribution to 66kV, 110kV, 220kV and 440kV transmission. The work includes both air-insulated (AIS) and gas-insulated (GIS) substations.

Does Tachyons Energy install solar power systems?

Yes. The company installs solar power plants from household rooftop systems to commercial, industrial and megawatt-scale utility-tied projects. Systems can be grid-tied, hybrid with battery backup, off-grid, or combined with a battery energy storage system (BESS), and for megawatt plants the company also builds the evacuation substation and line.

What is MoniTach?

MoniTach — The Tachyons Yard Intelligence is the company’s remote monitoring system for 220kV/440kV switchyards and control panels. It tracks breaker status, SF6 gas density, transformer temperatures, trip-circuit health and thermal hotspots over an optical-fibre link, so operators do not need to enter the energised yard to read gauges. It communicates over IEC 61850 and Modbus.

How do I get a quotation for an electrical or solar project?

Use the RFQ portal on the contact page. Select the scope of work, add the voltage class, location and any drawings or tender references you have, and a project engineer reviews the request and comes back with clarifications or a techno-commercial offer.

Request for quotation

Planning a substation, panel or monitoring project?

Share the voltage class, scope and site location. Our engineers will review the single-line diagram or tender specification and come back with a technical and commercial response.

11kV · 33kV · 66kV · 110kV · 220kV · 440kV